← Implementation differences · ecoinvent and SimaPro 1.03

BAFU 2026 v1 · EF 3.1

Ionising radiation

BAFU 2026 v1, Ionising radiation: ecoinvent 3.12 and EF 3.1 adapted 1.03

Engine version
volca 0.16.0 (73b86ac, v0.16.0, linux)
Measured on
Comparison measurements
DatabaseBAFU 2026 v1
MethodEF 3.1
IndicatorIonising radiation
Category in ecoinvent 3.12ionising radiation: human health (kBq U235-Eq)
Category in EF 3.1 adapted 1.03Ionising radiation (kBq U-235 eq)
Activities scored11,947
Activities compared11,754
Activities left out (a zero, opposite signs, or scored on one side only)193
Median ratio (EF 3.1 adapted 1.03 / ecoinvent 3.12)1.0006
Share outside the band1% outside 1%
Largest relative deviation+21.85%
Activity with largest deviationEthylene glycol, at plant
BAFU 2026 v1, Ionising radiation: ecoinvent 3.12 and EF 3.1 adapted 1.03
Each point is one activity of BAFU 2026 v1, scored by VoLCA twice: under ecoinvent 3.12 ('ionising radiation: human health') across, under EF 3.1 adapted 1.03 ('Ionising radiation') up, in kBq U235-Eq (kBq U-235 eq as EF 3.1 adapted 1.03 writes it). Nothing else differs, so a point off the black line is the two implementations disagreeing on that activity. The grey band is 1%. 11,754 activities are compared. 193 more have a zero on a side or two opposite signs, and no ratio describes them. Median ratio 1.0006, 1.00% outside the band. Neither implementation is taken as the reference.