← Implementation differences · openLCA and ecoinvent

BAFU 2026 v1 · EF 3.1

Particulate matter

BAFU 2026 v1, Particulate matter: openLCA 2.8.2 and ecoinvent 3.12

Engine version
volca 0.16.0 (73b86ac, v0.16.0, linux)
Measured on
Comparison measurements
DatabaseBAFU 2026 v1
MethodEF 3.1
IndicatorParticulate matter
Category in openLCA 2.8.2Particulate matter (disease incidence)
Category in ecoinvent 3.12particulate matter formation (disease incidence)
Activities scored11,947
Activities compared11,766
Activities left out (a zero, opposite signs, or scored on one side only)181
Median ratio (ecoinvent 3.12 / openLCA 2.8.2)1.0000
Share outside the band0.11% outside 1%
Largest relative deviation-8.52%
Activity with largest deviationPolystyrene, expandable, at plant
BAFU 2026 v1, Particulate matter: openLCA 2.8.2 and ecoinvent 3.12
Each point is one activity of BAFU 2026 v1, scored by VoLCA twice: under openLCA 2.8.2 ('Particulate matter') across, under ecoinvent 3.12 ('particulate matter formation') up, in disease incidence. Nothing else differs, so a point off the black line is the two implementations disagreeing on that activity. The grey band is 1%. 11,766 activities are compared. 181 more have a zero on a side or two opposite signs, and no ratio describes them. Median ratio 1.0000, 0.11% outside the band. Neither implementation is taken as the reference.