← Reliability

EcoSpold 2 · Calculation comparison

ecoinvent 3.12 cut-off, human toxicity: non-carcinogenic

A comparison of published impact results with VoLCA calculations from the same source data and the publisher’s impact factors. Points on the diagonal agree.

This page shows engine v0.13.0, which is not the newest measured. Compare the engine versions, or see the current comparisons.

Engine version
volca 0.13.0 (8c0396c, v0.13.0, linux)
Measured on
Comparison measurements and reference
Databaseecoinvent 3.12 cut-off
Source formatEcoSpold 2
Impact method collectionEF v3.1
Impact categoryhuman toxicity: non-carcinogenic
UnitCTUh
Activities compared19,837
Median ratio (VoLCA / published)1.0020
Comparison band1%
Activities outside the band2,293
Share outside the band11.56%
VerdictDisagrees: misses the agreement a release is held to
Points drawn2,161
Largest relative deviation+951.41%
Activity with largest deviationuranium production, in yellowcake
Published referenceecoinvent 3.12_cut-off_cumulative_lcia_xlsx.7z
ecoinvent 3.12 cut-off, human toxicity: non-carcinogenic
Each point is one activity: what ecoinvent 3.12 cut-off published for human toxicity: non-carcinogenic (CTUh), against what VoLCA computes from the same EcoSpold 2 source under the publisher's own EF v3.1 factors. The black line is equality and the grey band is 1%. 19,837 activities were compared; 2,293 fall outside the band, more than a picture can hold, so 1,984 of the 19,837 are drawn, evenly spaced over the published value whichever side of the band they fall, and the 177 of the 200 farthest from equality that this walk missed are added. Where several fall on one spot, at most three markers are drawn there, since a fourth would not darken it. Median ratio 1.0020, 11.56% outside the band. This misses the agreement a release is held to: at most 5% of activities outside the band and a median ratio inside it.